Current and future role of CT and advanced CT applications in inflammatory arthritis in the clinic and trials

Torabi M, Lenchik L, Beaman FD, et al. ACR Appropriateness Criteria® acute hand and wrist trauma. J Am Coll Radiol. 2019;16(5):S7–17.

Article  PubMed  Google Scholar 

Ulas ST, Diekhoff T. Computed tomography—current status and future directions for arthritis imaging. Ther Adv Musculoskelet Dis. 2024;16:1759720X241287373.

Article  PubMed  PubMed Central  Google Scholar 

Teh J, McQueen F, Eshed I, Plagou A, Klauser A. Advanced imaging in the diagnosis of gout and other crystal arthropathies. Seminars in musculoskeletal radiology. Thieme Medical Publishers. 2018;225–236

Diekhoff T, Eshed I, Radny F, et al. Choose wisely: imaging for diagnosis of axial spondyloarthritis. Ann Rheum Dis. 2022;81(2):237–42.

Article  CAS  PubMed  Google Scholar 

Diekhoff T, Ulas ST, Poddubnyy D, et al. Ultra-low-dose CT detects synovitis in patients with suspected rheumatoid arthritis. Ann Rheum Dis. 2019;78(1):31–5.

Article  PubMed  Google Scholar 

Omoumi P, Verdun FR, Becce F. Optimization of radiation dose and image quality in musculoskeletal CT: emphasis on Iterative Reconstruction Techniques (Part 2). Semin Musculoskelet Radiol. 2015;19(5):422–30. https://doi.org/10.1055/s-0035-1569254.

Fritz J, Kijowski R, Recht MP. Artificial intelligence in musculoskeletal imaging: a perspective on value propositions, clinical use, and obstacles. Skeletal Radiol. 2022;51(2):239–43.

Article  PubMed  Google Scholar 

Ibad HA, de Cesar NC, Shakoor D, et al. Computed tomography: state-of-the-art advancements in musculoskeletal imaging. Invest Radiol. 2023;58(1):99–110.

Article  PubMed  Google Scholar 

Alagic Z, Bujila R, Enocson A, Srivastava S, Koskinen SK. Ultra-low-dose CT for extremities in an acute setting: initial experience with 203 subjects. Skeletal Radiol. 2020;49:531–9.

Article  PubMed  Google Scholar 

Lawrence RL, Nicholson L, Lee EC, Napier K, Zmistowski B, Rainbow MJ. Geometric accuracy of low-dose CT scans for use in shoulder musculoskeletal research applications. Med Eng Phys. 2024;130:104214.

Article  PubMed  Google Scholar 

Orkut S, Gillet R, Granero J, et al. Assessment of scapholunate instability on 4D CT scans in patients with inconclusive conventional images. Radiology. 2023;308(3):e230193.

Article  PubMed  Google Scholar 

Demehri S, Baffour FI, Klein JG, et al. Musculoskeletal CT imaging: state-of-the-art advancements and future directions. Radiology. 2023;308(2):e230344.

Article  PubMed  Google Scholar 

Ulas ST, Hermann KG, Makowski MR, et al. Perfusion in hand arthritis on dynamic contrast-enhanced computed tomography: a randomized prospective study using MRI as a standard of reference. Skeletal Radiol. 2021;50(1):59–68.

Article  PubMed  Google Scholar 

Orkut S, Gillet R, Hossu G, et al. Kinematic 4D CT case-control study of wrist in dart throwing motion “in vivo”: comparison with other maneuvers. Eur Radiol. 2022;32(11):7590–600.

Article  PubMed  Google Scholar 

Scott DL, Wolfe F, Huizinga TW. Rheumatoid arthritis. Lancet. 2010;376(9746):1094–108.

Article  PubMed  Google Scholar 

Combe B, Landewe R, Daien CI, et al. 2016 update of the EULAR recommendations for the management of early arthritis. Ann Rheum Dis. 2017;76(6):948–59.

Article  PubMed  Google Scholar 

Ulas ST, Ziegeler K, Richter ST, et al. Contrast-enhanced CT techniques and MRI perform equally well in arthritis imaging of the hand: a prospective diagnostic accuracy study. Eur Radiol. 2022;32(9):6376–83.

Article  CAS  PubMed  PubMed Central  Google Scholar 

Forghani R, De Man B, Gupta R. Dual-energy computed tomography: physical principles, approaches to scanning, usage, and implementation: Part 1. Neuroimaging Clin N Am. 2017;27(3):371–84.

Article  PubMed  Google Scholar 

Johnson TR, Krauss B, Sedlmair M, et al. Material differentiation by dual energy CT: initial experience. Eur Radiol. 2007;17(6):1510–7.

Article  PubMed  Google Scholar 

Bongartz T, Glazebrook KN, Kavros SJ, et al. Dual-energy CT for the diagnosis of gout: an accuracy and diagnostic yield study. Ann Rheum Dis. 2015;74(6):1072–7.

Article  CAS  PubMed  Google Scholar 

Choi HK, Al-Arfaj AM, Eftekhari A, et al. Dual energy computed tomography in tophaceous gout. Ann Rheum Dis. 2009;68(10):1609–12.

Article  CAS  PubMed  Google Scholar 

Ottaviani S. Imaging follow-up of MSU crystal depletion. Gout, Urate, and Crystal Deposition Disease. 2024;2(1):34–44.

Article  Google Scholar 

Ghazi Sherbaf F, Sair HI, Shakoor D, et al. DECT in detection of vertebral fracture-associated bone marrow edema: a systematic review and meta-analysis with emphasis on technical and imaging interpretation parameters. Radiology. 2021;300(1):110–9.

Article  PubMed  Google Scholar 

Diekhoff T, Scheel M, Hermann S, Mews J, Hamm B, Hermann KA. Osteitis: a retrospective feasibility study comparing single-source dual-energy CT to MRI in selected patients with suspected acute gout. Skeletal Radiol. 2017;46(2):185–90.

Article  PubMed  Google Scholar 

Jans L, De Kock I, Herregods N, et al. Dual-energy CT: a new imaging modality for bone marrow oedema in rheumatoid arthritis. Ann Rheum Dis. 2018;77(6):958–60.

Article  PubMed  Google Scholar 

Fukuda T, Umezawa Y, Tojo S, Yonenaga T, Asahina A, Nakagawa H, Fukuda K. Initial Experience of using dual-energy ct with an iodine overlay image for hand psoriatic arthritis: comparison study with contrast-enhanced MR imaging. Radiology. 2017;284(1):134–142. https://doi.org/10.1148/radiol.2016161671.

Ogiwara S, Fukuda T, Kawakami R, Ojiri H, Fukuda K. Anatomical analysis of inflammation in hand psoriatic arthritis by dual-energy CT iodine map. Eur J Radiol Open. 2021;8:100383.

Article  PubMed  PubMed Central  Google Scholar 

Kayama R, Fukuda T, Ogiwara S, et al. Quantitative analysis of therapeutic response in psoriatic arthritis of digital joints with dual-energy CT iodine maps. Sci Rep. 2020;10(1):1225.

Article  CAS  PubMed  PubMed Central  Google Scholar 

Wittig TM, Ziegeler K, Kreutzinger V, et al. Dual-energy computed tomography collagen density mapping of the cranio-cervical ligaments-a retrospective feasibility study. Diagnostics (Basel). 2022;12(12):2966.

Article  PubMed  Google Scholar 

Ulas ST, Ziegeler K, Richter ST, et al. Virtual monochromatic images from dual-energy computed tomography do not improve the detection of synovitis in hand arthritis. Diagnostics (Basel). 2022;12(8):1819.

Google Scholar 

Goo HW, Goo JM. Dual-energy CT: new horizon in medical imaging. Korean J Radiol. 2017;18(4):555–69.

Article  PubMed  PubMed Central  Google Scholar 

Leng S, Yu L, Fletcher JG, McCollough CH. Maximizing iodine contrast-to-noise ratios in abdominal CT imaging through use of energy domain noise reduction and virtual monoenergetic dual-energy CT. Radiology. 2015;276(2):562–70.

Article  PubMed  Google Scholar 

Willemink MJ, Persson M, Pourmorteza A, Pelc NJ, Fleischmann D. Photon-counting CT: technical principles and clinical prospects. Radiology. 2018;289(2):293–312.

Article  PubMed  Google Scholar 

Greffier J, Villani N, Defez D, Dabli D, Si-Mohamed S. Spectral CT imaging: technical principles of dual-energy CT and multi-energy photon-counting CT. Diagn Interv Imaging. 2023;104(4):167–77.

Article  PubMed  Google Scholar 

Quintiens J, van Lenthe GH. Photon-Counting Computed Tomography for Microstructural Imaging of Bone and Joints. Curr Osteoporos Rep. 2024;22(4):387–95. https://doi.org/10.1007/s11914-024-00876-0.

Bayrak YE, Özer T, Anik Y, Balci S, Aydin D, Şahin N, Sönmez HE. Assessment of sacroiliitis using zero echo time magnetic resonance imaging: a comprehensive evaluation. Pediatr Radiol. 2025. https://doi.org/10.1007/s00247-025-06201-w.

Ulas ST, Diekhoff T, Hermann KGA, Poddubnyy D, Hamm B, Makowski MR. Susceptibility-weighted MR imaging to improve the specificity of erosion detection: a prospective feasibility study in hand arthritis. Skeletal Radiol. 2019;48(5):721–8.

Article  PubMed  Google Scholar 

Ulas ST, Ziegeler K, Richter ST, et al. CT-like images in MRI improve specificity of erosion detection in patients with hand arthritis: a diagnostic accuracy study with CT as standard of reference. RMD Open. 2022;8(1):e002089.

Article  PubMed  PubMed Central 

Comments (0)

No login
gif