Rosier P, Schaefer W, Lose G, Goldman HB, Guralnick M, Eustice S, Dickinson T, Hashim H. International continence society good urodynamic practices and terms 2016: Urodynamics, uroflowmetry, cystometry, and pressure-flow study. Neurourol Urodyn. 2017;36(5):1243–60.
Erdem E, Akbay E, Doruk E, Cayan S, Acar D, Ulusoy E. How reliable are bladder perceptions during cystometry? Neurourol Urodyn. 2004;23(4):306–10.
Gupta A, Defreitas G, Lemack GE. The reproducibility of urodynamic findings in healthy female volunteers: results of repeated studies in the same setting and after short-term follow-up. Neurourol Urodyn. 2004;23(4):311–6.
Abelson B, Majerus S, Sun D, Gill BC, Versi E, Damaser MS. Ambulatory urodynamic monitoring: state of the art and future directions. Nat Rev Urol. 2019;16(5):291–301.
Article PubMed PubMed Central Google Scholar
Sheen D, Kolli H, Nagle AS, Cullingsworth Z, Vinod NN, Naimi HA, De Wachter SG, Mazzeo SE, Stothers L, Speich JE, Klausner AP. Validation of a real-time bladder sensation meter during oral hydration in healthy adults: repeatability and effects of fill rate and ultrasound probe pressure. Low Urin Tract Symptoms. 2019;11(4):224–31.
Article PubMed PubMed Central Google Scholar
Vinod NN, Nagle AS, Naimi HA, Kolli H, Sheen D, Nandanan N, Carucci LR, Speich JE, Klausner AP. Bladder volume correction factors measured with 3D ultrasound and BladderScan. Can J Urol. 2019;26(4):9829–34.
PubMed PubMed Central Google Scholar
Zhao L, Liao L, Gao L, Gao Y, Chen G, Cong H, Wang Y, Liao X. Effects of bladder shape on accuracy of measurement of bladder volume using portable ultrasound scanner and development of correction method. Neurourol Urodyn. 2019;38(2):653–9.
Nagle AS, Bernardo RJ, Varghese J, Carucci LR, Klausner AP, Speich JE. Comparison of 2D and 3D ultrasound methods to measure serial bladder volumes during filling: Steps toward development of non-invasive ultrasound urodynamics. Bladder (San Franc). 2018;5(1).
De Nunzio C, Lombardo R, Cicione A, Trucchi A, Carter S, Tema G, Nacchia A, Vicentini C, Tubaro A. The role of bladder wall thickness in the evaluation of detrusor underactivity: Development of a clinical nomogram. Neurourol Urodyn. 2020;39(4):1115–23.
Gray T, Phillips L, Li W, Buchanan C, Campbell P, Farkas A, Abdi S, Radley S. Evaluation of bladder shape using transabdominal ultrasound: Feasibility of a novel approach for the detection of involuntary detrusor contractions. Ultrasound. 2019;27(3):167–75.
Article PubMed PubMed Central Google Scholar
Glass Clark S, Nagle AS, Bernardo R, Vinod N, Carucci L, Carroll A, Speich J, Klausner AP. Use of ultrasound urodynamics to identify differences in bladder shape between individuals with and without overactive bladder. Female Pelvic Med Reconstr Surg. 2020;26(10):635–9.
Li R, Nagle AS, Maddra KM, Vinod N, Prince SA, Tensen SI, Thapa D, Sebastian B, Sethi D, Alattar A, Carucci LR, Klausner AP, Speich JE. Irregular bladder shapes identified in women with overactive bladder: an ultrasound nomogram. Am J Clin Exp Urol. 2021;9(5):367–77.
PubMed PubMed Central Google Scholar
Nenadic I, Mehrmohammadi M, Urban MW, Alizad A, Greenleaf JF, Fatemi M. In vivo patient measurements of bladder elasticity using Ultrasound Bladder Vibrometry (UBV). Conf Proc IEEE Eng Med Biol Soc. 2013;2013:113–6.
Rosen DP, Husmann DA, Mynderse LA, Kelly TF Jr, Alizad A, Fatemi M. Detrusor overactivity assessment using ultrasound bladder vibrometry. Physiol Meas. 2021;42(10)
Sturm RM, Yerkes EB, Nicholas JL, Snow-Lisy D, Diaz Saldano D, Gandor PL, Halline CG, Rosoklija I, Rychlik K, Johnson EK, Cheng EY. Ultrasound shear wave elastography: a novel method to evaluate bladder pressure. J Urol. 2017;198(2):422–9.
Zhang X, Husmann DA, Mynderse LA, Alizad A, Fatemi M. Non-invasive assessment of urinary bladder compliance using ultrasound: first validation study based on clinical urodynamic study. Ann Transl Med. 2021;9(7):547.
Article PubMed PubMed Central Google Scholar
Nagle AS, Klausner AP, Varghese J, Bernardo RJ, Colhoun AF, Barbee RW, Carucci LR, Speich JE. Quantification of bladder wall biomechanics during urodynamics: A methodologic investigation using ultrasound. J Biomech. 2017;61:232–41.
Article PubMed PubMed Central Google Scholar
Nagle AS, Cullingsworth ZE, Li R, Carucci LR, Klausner AP, Speich JE. Bladder wall micromotion measured by non-invasive ultrasound: initial results in women with and without overactive bladder. Am J Clin Exp Urol. 2021;9(1):44–52.
PubMed PubMed Central Google Scholar
Rosier P, Gammie A, Valdevenito JP, Speich J, Smith P, Sinha S, members of the ICSWGPFS. ICS-SUFU standard: Theory, terms, and recommendations for pressure-flow studies performance, analysis, and reporting. Part 2: analysis of PFS, reporting, and diagnosis. Neurourol Urodyn. 2023;42(8):1603–27.
Rosier P, Valdevenito JP, Smith P, Sinha S, Speich J, Gammie A, Members of the ICSWGPFS. ICS-SUFU standard: Theory, terms, and recommendations for pressure-flow studies performance, analysis, and reporting. Part 1: background theory and practice. Neurourol Urodyn. 2023;42(8):1590–602.
Swavely NR, Speich JE, Klausner AP. Artifacts and abnormal findings may limit the use of asymptomatic volunteers as controls for studies of multichannel urodynamics. Minerva Urologica e Nefrologica = The Italian Journal of Urology and Nephrology. 2021;73(5):655–61.
Leitner L, Walter M, Sammer U, Knupfer SC, Mehnert U, Kessler TM. Urodynamic investigation: a valid tool to define normal lower urinary tract function? PLoS One. 2016;11(10):e0163847.
Article PubMed PubMed Central Google Scholar
Gammie A, Speich JE, Damaser MS, Gajewski JB, Abrams P, Rosier P, Arlandis S, Tarcan T, Finazzi Agro E. What developments are needed to achieve less-invasive urodynamics? ICI-RS 2019. Neurourol Urodyn. 2020;39 Suppl 3(n/a):S36–S42.
Medina Lucena H, Tincello DG. Validation of a water-load protocol to define the pattern of bladder sensation. Int Urogynecol J. 2019;30(5):767–72.
De Wachter SG, Heeringa R, Van Koeveringe GA, Winkens B, Van Kerrebroeck PE, Gillespie JI. "Focused introspection" during naturally increased diuresis: description and repeatability of a method to study bladder sensation non-invasively. Neurourol Urodyn. 2014;33(5):502–6.
Heeringa R, van Koeveringe GA, Winkens B, van Kerrebroeck PE, de Wachter SG. Degree of urge, perception of bladder fullness and bladder volume--how are they related? J Urol. 2011;186(4):1352–7.
Lai HH, Naliboff B, Liu AB, Amundsen CL, Shimony JS, Magnotta VA, Shaffer JJ, Gilliam RL, Wiseman JB, Helmuth ME, Andreev VP, Kirkali Z, Harte SE, Group LS. The LURN research network neuroimaging and sensory testing (NIST) study: design, protocols, and operations. Contemp Clin Trials. 2018;74:76–87.
Article PubMed PubMed Central Google Scholar
Kojima M, Inui E, Ochiai A, Naya Y, Ukimura O, Watanabe H. Noninvasive quantitative estimation of infravesical obstruction using ultrasonic measurement of bladder weight. J Urol. 1997;157(2):476–9.
Article CAS PubMed Google Scholar
Latthe P, Middleton L, Rachaneni S, McCooty S, Daniels J, Coomarasamy A, Balogun M, Duckett J, Thakar R, Goranitis I, Roberts T, Deeks J, Group BUSC. Ultrasound bladder wall thickness and detrusor overactivity: a multicentre test accuracy study. BJOG. 2017;124(9):1422–9.
Article CAS PubMed Google Scholar
Rachaneni S, McCooty S, Middleton LJ, Parker VL, Daniels JP, Coomarasamy A, Verghese TS, Balogun M, Goranitis I, Barton P, Roberts TE, Deeks JJ, Latthe P, Bladder Ultrasound Study Collaborative G. Bladder ultrasonography for diagnosing detrusor overactivity: test accuracy study and economic evaluation. Health Technol Assess. 2016;20(7):1–150.
Article PubMed PubMed Central Google Scholar
Oelke M, Hofner K, Jonas U, Ubbink D, de la Rosette J, Wijkstra H. Ultrasound measurement of detrusor wall thickness in healthy adults. Neurourol Urodyn. 2006;25(4):308–18.
Chen YZ, Peng L, Zhang C, Xu S, Luo DY. Bladder sonomorphological tests in diagnosing bladder outlet obstruction in patients with lower urinary tract symptoms: a systematic review and meta-analysis. Urol Int. 2023;107(4):327–35.
Presicce F, DEN C, Gacci M, Finazzi Agro E, Tubaro A. Non-invasive ultrasound measurements in male patients with LUTS and benign prostatic obstruction: implication for diagnosis and treatment. Minerva Urol Nefrol. 2017;69(3):220–33.
Rademakers KL, van Koeveringe GA, Oelke M, Force Research Group, Maastricht and Hannover. Ultrasound detrusor wall thickness measurement in combination with bladder capacity can safely detect detrusor underactivity in adult men. World J Urol. 2017;35(1):153–9.
Damaser MS, Lehman SL. Does it matter, the shape of the bladder? Neurourol Urodyn. 1993;12(3):277–80.
Comments (0)